| Working rate | Evaluate complete-strip presentation, cavity imaging and reject timing together. | Evaluate spacing, views and rejection for the actual container geometry. |
| Format inputs | Cavity count, pitch, connecting web, wall and seal geometry. | Body shape, opening feature, wall and seal geometry. |
| Optical arrangement | Select views and illumination for each cavity without losing strip identity. | Select end and side views that suit the container support. |
| Particle assessment | Challenge relevant cavities and positions with representative products and defect samples. | Challenge the observed liquid regions and relevant defect positions. |
| Integrity test | Define the method and tested regions independently of vision. | Define the method and package presentation independently of vision. |
| View coverage | Record the observed regions and any occlusion caused by connecting webs or holders. | Record the observed regions and any occlusion caused by holders or opening features. |
| Defect classification | Separate product particles, wall inclusions, moulding defects and seal appearance. | Separate product, body, closure and fill-level observations. |
| Format change | Verify cavity pitch, support, recipes and the strip-to-result association. | Verify guide settings, support, recipes and container tracking. |
| Reject unit | Specify whole-strip rejection or separately engineered unit handling. | Track each container to the accepted or rejected destination. |
| Vision utilities | Determine electrical and other services from the selected inspection configuration. | Determine electrical and other services from the selected inspection configuration. |
| Integrity-test utilities | Determine the requirements of the selected test method and protection system. | Determine the requirements of the selected test method and protection system. |
| Qualification basis | Agree product samples, defect challenges, records and operating procedures. | Agree product samples, defect challenges, records and operating procedures. |
| Vision footprint | Allow access for strip entry, optics, reject collection and maintenance. | Allow access for container entry, optics, reject collection and maintenance. |
| Integrity-test footprint | Allow the required test presentation, safety access and transfer distance. | Allow the required test presentation, safety access and transfer distance. |
| Labeling interface | Match label placement and subsequent checks to the strip or unit route. | Match label placement and subsequent checks to the selected bottle or ampoule. |