Prepare the powder
Define powder condition at transfer, the working charge and exposure controls. Specify milling or contained transfer only where needed.
Process expertise. Chinese manufacturing. Global perspective.
Production line
A reservoir inhaler line fills the powder charge into the specified reservoir and joins it to the inhaler’s metering and housing components. The manufacturing fill is the reservoir charge; the device subsequently meters doses during use. Define those two functions separately when setting acceptance criteria.
A reservoir carries a working powder charge that feeds the inhaler’s metering mechanism during use. Its inlet and internal geometry influence how powder enters and remains available to that mechanism. Bridging or retained material affects manufacturing fill behaviour, while insert placement and closure affect the assembled device. Charge verification and finished-device performance therefore remain distinct checks.
Example project input
This is a material-planning example for device development. The reservoir charge, dose delivered by the device and filler hold-up are separate quantities.
60
Reservoirs in a mechanical trial
2 g
Illustrative powder charge per reservoir
120 g
Powder delivered into the reservoirs
—
Process options
Compare the powder's handling behaviour with the reservoir shape and the device's dose metering mechanism.
Define powder condition at transfer, the working charge and exposure controls. Specify milling or contained transfer only where needed.
Establish reservoir orientation and fill verification before closing. Trial the actual powder and inlet geometry to check bridging or retained powder.
Join the reservoir to the metering mechanism and agree the finished-device tests. Define how the accepted inhaler enters protective packing.
Integrated production · Process route
The four positions in the assembly drawing identify housing preparation, reservoir charging, insertion and closure.
The four positions in the assembly drawing identify housing preparation, reservoir charging, insertion and closure.
Select a numbered area to see the operation and related equipment.
Technology
Confirm the receiving hopper connection, cleaning access and how powder is released. Inspect retained material at the end of a run.
Explore equipment →
Technology
Choose a feeder that can handle the powder at the reservoir opening. Verify the bulk fill before the device body conceals the reservoir.
Explore equipment →
The open reservoir makes fill and seating features accessible before the housing closes. Linking those observations to the assembled device separates a powder-feed problem from a component or closure problem. The four illustrated positions describe that assembly progression rather than a complete powder-processing factory.
Track charge weight and record visible bridging at the inlet during a representative run. Recheck the first fills after a pause and keep the powder condition with the results.
Agree which interfaces can be viewed before closure and retain marked devices for the specified functional test. Link results to the corresponding filling records.
Define prepared-powder delivery, reservoir orientation, filling, insert placement and closure for the selected device drawing. Specify which features can be inspected before enclosure and how accepted devices transfer to their protective packs. Powder conditioning and micronization are included only where required by the formulation.
Confirm the powder and reservoir geometry, and establish the permitted condition at filling.
Define reservoir fill mass, insert placement and closure checks separately. Delivered-dose and aerosol performance belong to the finished-device assessment, not the amount initially loaded into the reservoir.
Identify what can still be inspected after closing and what must be checked beforehand. Set the finished pack interface.
Compare the powder's handling behaviour with the reservoir shape and the device's dose metering mechanism.
Learn moreCheck the reservoir closure and device function after normal transfer and packing.
Learn moreIdentify the contact parts and format tooling for Reservoir Inhaler Filling & Assembly Lines. Agree access for cleaning, the spares to hold and the operating records the site will need.
Learn moreShare dosage form, starting material and finished presentation.
Request product information
Brochure
Reservoir Inhaler Filling & Assembly Lines
Available by enquiry
Request product information ↗Case
Reservoir Inhaler Filling & Assembly Lines
Available by enquiry
Discuss project references ↗2 resources
No. The line loads a working powder charge into the reservoir. The inhaler’s metering mechanism determines the individual dose presentation during use. Specify reservoir fill checks and finished-inhaler performance tests separately.
Record the material condition and inspect the inlet and feed path for bridging or retained powder. Compare fills before and after restart using the agreed measurement method. Establish refill and recovery procedures with representative powder and the actual reservoir geometry.
They present and meter powder differently. A blister line fills separate sealed dose pockets; a reservoir device receives a bulk charge and its own metering components. Assess each device configuration independently rather than assuming interchangeable tooling.
It is an assembly sequence showing housing preparation, reservoir charging, insert placement and device closure. It is not a full factory layout or a promise that all powder-preparation and packaging equipment is included.
YOUR PRIVACY
This website currently uses no analytics or marketing trackers. You can return to these settings at any time using the footer.
Essential page navigation, inquiry submission and your saved privacy preference.
No analytics cookies, analytics scripts or third-party measurement are enabled.
No advertising cookies, remarketing pixels or embedded social trackers are enabled.
Saving stores your preference in this browser only. It does not enable optional tracking. See our Privacy Statement for inquiry data information.
CONTACT PREASYS
Share your product, process and project priorities so we can direct your enquiry to the appropriate team.