Tube filling meters product through the open tail of an oriented tube, then closes that tail using a process matched to the tube construction.

Tube filling and closing equipment in a guarded enclosure

Tube Filling & Sealing

Fill the tube, then form its closure

Dosing and sealing follow different material requirements

Tube holders establish position while the nozzle delivers the product. Withdrawal and cutoff keep material away from the open tail before closing. Metal tubes are closed by a selected fold; plastic or laminate structures require a compatible sealing process. Tube material, fill rheology and the finished closure are evaluated as one package.

Filling nozzle positioned above an open tube

Process at a glance

The fill and the tail closure have separate acceptance criteria and must share the available operating cycle.

Dose

Fill without contaminating the tube tail

Close

Use the method required by the tube construction

Filling technologies

Filling technology

Peristaltic pump

A flexible tube carries the liquid while rotating rollers control dosing. The product contacts the tube rather than the pump mechanism. This principle is used when a disposable product path and gentle handling are priorities. Tubing selection, product compatibility and the changeover procedure should be reviewed for each application.

Explore technology
Diagram connecting a peristaltic pump to the product filling path

Filling technology

Piston pump

A piston draws liquid into a cylinder and then dispenses a measured volume through the outlet. The selected piston, valve and product-contact materials determine the application range. Review viscosity, cleaning requirements and the required filling volume together with the product and container format.

Explore technology
Rotary piston metering equipment connected to a set of filling heads

Filling technology

Time pressure

Controlled pressure moves liquid through a filling valve. The opening time and supply conditions determine the dispensed quantity. Product properties, pressure stability and the valve configuration are evaluated together when setting up the filling process.

Explore technology
Diagram of a time-pressure dosing vessel and filling heads

Filling technology

Mass flow

A flow sensor measures the product passing through the filling path and provides feedback to the dosing valve. The process is evaluated around the required fill mass, product behaviour and cleaning strategy. Sensor selection and the control sequence depend on the application.

Explore technology
Product flow path with a mass flow meter and dispensing points
Technology 1 of 4

Process challenges

Viscosity, incomplete charging and air affect delivered quantity differently. Dose variation is assessed at the actual product condition.

Read details

Viscosity, incomplete charging and air affect delivered quantity differently. Dose variation is assessed at the actual product condition.

A product string can bridge into the seal area after metering stops. Cutoff and nozzle withdrawal must protect the tail before closure.

Format change establishes tube support, nozzle position, orientation and closing settings. Its duration follows the actual tasks and clearance requirements.

Metal, plastic and laminate tubes have different closure interfaces. A machine requires the correct stations and tooling for each selected material.

A heat-sensitive formulation still requires a sound package closure. The actual thermal or ultrasonic exposure is assessed against both seal and product criteria.

Aseptic suitability includes the prepared tube, product path, open exposure and transfer into closing. It is not established by a filler label.

Gas treatment can change the atmosphere around the product; its effect depends on exposure, flow and the closure sequence.

Cleaning must reach retained product in valves, passages and nozzles. Accessible surfaces alone do not establish cleaning effectiveness.

A higher operating rate changes the time available for dosing and closing. Accepted output includes fill and seal results at the selected condition.

Technical data & features

Tube construction, open-tail dimensions, holder support and product cutoff determine the filling-nozzle and tail-closing arrangement.

Filling nozzle positioned above an open tube

Closing the tube tail

Metal folding deforms the tube end through a defined fold and compression sequence. Fold geometry and material condition determine the resulting closure.

Hot-air sealing heats the relevant inner sealing layer before the tail is pressed closed. Heating, compression and cooling must match the actual tube structure.

Ultrasonic joining applies localized mechanical energy at the sealing interface where suitable for the laminate. Its process window and product exposure need assessment with the actual tube.

Dosing and format control Metering selected for product rheology, air content and nozzle cutoff

Tube holders, orientation and setup

Different tube diameters and materials can change holders, feeding and closing tooling. Shared machine architecture does not imply a tooling-free change.

The product-contact path includes the supply, meter, valves and nozzle. Cleaning or sterilization tasks are defined for the installed arrangement.

Open-tube exposure and transfer to closing are separate process boundaries

Gas treatment where the formulation requires it

Coding places the approved batch or product data on the selected part of the tube. Code readability and closure quality are distinct checks.

Cleaning access and operating records

Tube feeding must preserve orientation and presentation to the holder. Product supply must maintain the conditions used to establish the dosing cycle.

Decision Metal tube Plastic tube Laminate tube Product path
Cycle boundary Fold and compression time Heat, compression and cooling Selected sealing process Charging, dosing and cutoff
Quality attribute Fold geometry and closure Seal geometry and integrity Seal performance of the actual layers Delivered mass and retained product
Material input Tube alloy and tail condition Inner sealing layer Layer structure and thickness Viscosity, air and sensitivity
Geometry input Tail and holder dimensions Tail and holder dimensions Tail and holder dimensions Nozzle clearance and withdrawal
Changeover Holders and fold tooling Holders and heating/sealing setup Tooling for selected joining method Contact parts and dose settings
Process choice Specified fold sequence Compatible heat-seal sequence Compatible heat or ultrasonic sequence Selected metering principle
Verification Closure and package tests Closure and package tests Closure and package tests Dose and cleaning assessment

How it works

Evaluate tube dosing and tail closure

How is product at the tube tail investigated?

Observe nozzle withdrawal and the end of the dose, then inspect the open tail before closing. Compare the result with product temperature, supply and cutoff settings.

How is a sealing window assessed?

Use the actual tube construction and filled product. Compare closure geometry, strength and the specified integrity test over the proposed process settings.

How is changeover verified?

Identify the tube, holders and recipe; verify orientation, nozzle clearance and closing-tool setup. Evaluate the first fills and closures before releasing the format.

How should the preparation handoff be checked?

Compare the product at the supply vessel and dosing inlet after the planned hold. Record temperature, air and flow changes that can affect charging and cutoff.

Line integration

Empty tubes (metal / plastic / laminate) → Selected tube feeding

↓

Selected tube filling and tail-closing sequence:

Tube orientation and positioning → Product dosing → Selected gas treatment, if required

→ Material-specific tail closure → Selected coding → Ejection (sealed tube inspection)

↓

Sealed tubes → Checkweighing → Cartoning (vertical / horizontal cartoner) → Case packing

Read more

Sealed tubes → Checkweighing → Cartoning (vertical / horizontal cartoner) → Case packing

Upstream: prepared bulk from mixing or holding; empty tubes presented for the selected holders and orientation control.

Downstream: closed tubes pass the specified checks before entering the selected cartoner and case-packing route.

Aseptic use requires defined product, tube-exposure and closing boundaries with appropriate qualification evidence.

Connect the tube filling recipe, seal settings and reject record to the batch. Specify any data exchange with the site system.

Support throughout your project and production

Define the equipment scope

Tube construction, open-tail dimensions, holder support and product cutoff determine the filling-nozzle and tail-closing arrangement.

Learn more

Agree the acceptance test

Inspect the seal, code position and net contents after filling representative tube formats.

Learn more

Prepare for operation

Identify the contact parts and format tooling for Tube Filling & Sealing. Agree access for cleaning, the spares to hold and the operating records the site will need.

Learn more

Knowledge hub

2 resources

Frequently asked questions

Can one closure method serve metal and plastic tubes?

Generally they require different physical operations: metal is folded, while a plastic sealing layer is joined using a compatible process. The installed tooling must match the selected tube.

Does ultrasonic sealing eliminate all product heating?

No. It concentrates energy near the joining interface, but the actual exposure and closure result still require assessment for the tube and formulation.

Is tube-fill accuracy independent of the product?

No. Charging, entrained air, temperature, valve behaviour and cutoff influence delivered quantity. A stated tolerance needs its product and operating conditions.

Does clean-in-place capability make the line aseptic?

No. Cleaning and sterility assurance have different objectives. Aseptic filling requires a defined and qualified system boundary through closing.

Contact

Share the tube construction and drawing, product condition at filling, dose and required closure. Include the proposed preparation connection and downstream cartoning format.

Discuss your project →
Filling nozzle positioned above an open tube