Skip to content

Process expertise. Chinese manufacturing. Global perspective.

PREASYS

Equipment & technology

Automated Soft Mist Inhaler (SMI) Assembly & Micro-Filling Systems

Fill and close the liquid reservoir selected for a soft mist inhaler, then assemble it with the specified device components. The SMI manufacturing route is built around the actual reservoir and liquid path; reservoir filling, closure integrity and aerosol delivery are distinct process and product functions.

Soft-mist inhaler housing beside the removable container assembly

Soft Mist Inhaler Filling Line (SMI)

Liquid-reservoir filling and soft mist inhaler assembly

Match the filled reservoir to the dispensing mechanism

The filling station supplies liquid to a reservoir that later feeds the device mechanism. Container orientation, neck access and the liquid path affect dosing and closure, while the assembled mechanism determines how the formulation is metered and dispersed. Prepared reservoirs can arrive from a separate supplier or forming operation; manufacturing the container is not automatically part of the SMI filling machine. This is a liquid-device process, distinct from DPI powder filling and from propellant-charged aerosol manufacture.

Dosing head dispensing liquid into small device containers

Process at a glance

Reservoir filling and device assembly are the scope here. Container forming and integrity testing require their own selected process and evidence.

Fill

Meter liquid into the specified SMI reservoir

Assemble

Join reservoir and mechanism using the approved device sequence

Filling technologies

Filling technology

Peristaltic pump

A flexible tube carries the liquid while rotating rollers control dosing. The product contacts the tube rather than the pump mechanism. This principle is used when a disposable product path and gentle handling are priorities. Tubing selection, product compatibility and the changeover procedure should be reviewed for each application.

Explore technology
Diagram connecting a peristaltic pump to the product filling path

Filling technology

Piston pump

A piston draws liquid into a cylinder and then dispenses a measured volume through the outlet. The selected piston, valve and product-contact materials determine the application range. Review viscosity, cleaning requirements and the required filling volume together with the product and container format.

Explore technology
Rotary piston metering equipment connected to a set of filling heads

Filling technology

Time pressure

Controlled pressure moves liquid through a filling valve. The opening time and supply conditions determine the dispensed quantity. Product properties, pressure stability and the valve configuration are evaluated together when setting up the filling process.

Explore technology
Diagram of a time-pressure dosing vessel and filling heads

Filling technology

Mass flow

A flow sensor measures the product passing through the filling path and provides feedback to the dosing valve. The process is evaluated around the required fill mass, product behaviour and cleaning strategy. Sensor selection and the control sequence depend on the application.

Explore technology
Product flow path with a mass flow meter and dispensing points
Technology 1 of 4

Process challenges

Reservoir shape affects support and nozzle access. Fixtures establish a stable presentation for filling and closing.

Read details

Reservoir shape affects support and nozzle access. Fixtures establish a stable presentation for filling and closing.

The incoming reservoir state and preparation boundary determine handling requirements; automated forming is not proof of sterility.

Integrity detection depends on container, closure, product and the chosen method. A test result is interpreted within its established threshold.

The approved reservoir design determines closure material and joining process. A cap or crimp is assessed rather than assumed hermetic.

Assembly positions the filled reservoir and mechanism according to the device design, with specified joining and function checks.

Unit or tracked-position identity connects filling, closing and assembly status, including interrupted units.

Container-forming quality belongs to its own controlled process and accepted incoming specification; forming need not be part of the SMI filler.

Technical data & features

Container closure, fluid path cleanliness and the interface to the spray mechanism guide processing and assembly choices.

Dosing head dispensing liquid into small device containers

Reservoir handling, closing and assembly

The reservoir drawing and incoming state determine support and transfer. Any container-forming operation has its own material, tooling and preparation requirements; a formed reservoir is not presumed sterile simply because it is transferred automatically.

An integrity method evaluates the specified container and closure under defined conditions. Container material, geometry and product influence method selection and detection performance; no universal smallest-leak claim applies.

Dosing access and liquid release at the selected reservoir opening Closure placement and joining to the reservoir specification

Device-specific positioning and joining

The reservoir must arrive at assembly in the required closed state and orientation. Supports and joining tools preserve the protected fluid interfaces while the device components are positioned and secured.

A project may supply filled reservoirs, perform final device assembly, or connect both operations. The agreed boundary determines handling, checks and records rather than requiring every possible module.

Module Function
Container supply Prepared reservoir or a separately defined forming process.
Integrity testing Method and limits qualified for the actual container and closure.
Liquid filling Dosing path and nozzle arrangement matched to formulation and opening.
Closing Selected closure material and joining method.
Assembly Device-specific component presentation, positioning and joints.
Records Required unit or batch association with test and assembly disposition.
Parameter SMI
Container geometry Defines tooling support, access and preparation boundary.
Integrity-test rate Established for the selected method and test cycle.
Fill quantity Liquid charge in the reservoir, distinct from delivered mist dose.
Closure Specified cap, seal or other approved closing arrangement.
Assembly scope Actual stations required by the device design.
Project evidence Materials, drawings, equipment tests and defined product-validation responsibilities.

How it works

Operating sequence and process decisions

How is the incoming reservoir state established?

Identify whether reservoirs are supplied prepared or produced in an upstream process. Their condition and transfer boundary determine the handling and preparation tasks before filling; automatic transport does not itself establish sterility.

How does a shaped reservoir change filling?

The support fixture establishes orientation and nozzle access. Observe liquid release, air displacement and any residue around the opening using the actual reservoir, then evaluate the specified filled quantity.

How is an integrity test selected?

Relate the container material, closure and product to the proposed test method. Use agreed challenge units and operating conditions to establish detection performance and the scope of the result.

How is closure quality assessed?

The closing operation forms the specified joint. Its geometry or process signals are evaluated together with the required completed-container tests rather than treating a crimp or cap as inherently hermetic.

How is reservoir assembly connected to mist delivery?

The reservoir is positioned and joined according to the device design. Assembly checks establish specified features; the finished device and formulation tests evaluate delivery and aerosol behaviour.

How do results remain attached to the unit?

Keep the reservoir or tracked position associated with fill, closure and assembly status. Challenge rejects and transfer interruptions so an unresolved result cannot become an accepted finished unit.

Soft mist inhaler processing line. Explore container handling, identification, device assembly and the protected processing area.

Production line · Equipment context

Soft mist inhaler processing line

Explore the process areas on the production line associated with this equipment.

Skip tour
Production layout 6 equipment areas · Scroll to explore

Explore container handling, identification, device assembly and the protected processing area.

Related production lines: Soft Mist Inhaler Filling & Assembly Lines · Liquid Inhalation Production Lines

Line integration

Prepared reservoir + liquid formulation + specified closure and device components

↓

The selected liquid-container and device route

Reservoir presentation and preparation checks at the agreed boundary

Liquid filling → specified closure placement and joining Required integrity and assembly checks → device assembly and final inspection ↓ Released devices → labelling and secondary packaging Upstream: prepared reservoirs and components, with formulation supplied under its defined conditions

Downstream: accepted filled reservoirs or assembled devices at the agreed boundary

Identity and process state remain associated through filling, closing and assembly. A failed integrity or joining result follows the affected unit into rejection, including after a stopped transfer.

Fluid-path and assembly-tool maintenance

Dosing components, reservoir supports and closure tools affect fill and fit. Cleaning or tool adjustment is followed by the corresponding fill, closure and joining checks. Device-performance testing establishes the resulting spray behaviour separately from equipment acceptance.

Support throughout your project and production

Define the equipment scope

Container closure, fluid path cleanliness and the interface to the spray mechanism guide processing and assembly choices.

Learn more

Agree the acceptance test

Check the filled container and assembled device separately before the final functional test.

Learn more

Prepare for operation

Identify the contact parts and format tooling for Soft Mist Inhaler Filling Line (SMI). Agree access for cleaning, the spares to hold and the operating records the site will need.

Learn more

Knowledge hub

2 resources

Frequently asked questions

Does SMI equipment fill inhalation powder?

The SMI scope here uses a liquid reservoir and its device mechanism. Powder filling belongs to capsule, blister or reservoir DPI equipment and has different handling and dosing requirements.

Is container forming always included?

No. Prepared reservoirs may be supplied separately. Include forming only where the selected container and project scope require it, with its own material and preparation assessment.

Must the closure be an aluminium cap?

The approved reservoir and device drawing determines the closure. Select the placement, joining and integrity checks for that design rather than assume one cap material or process.

Does reservoir fill accuracy establish the mist dose?

No. It describes the liquid charge placed in the reservoir. The device metering and dispersion mechanism and the formulation determine delivered-dose and aerosol performance.

Contact

Share the SMI reservoir, closure and mechanism drawings, liquid formulation and incoming component state. These establish filling, joining and verification boundaries without assuming that container forming is part of the line.

Discuss your project →
Dosing head dispensing liquid into small device containers