Skip to content

Process expertise. Chinese manufacturing. Global perspective.

PREASYS

Equipment & technology

Automated Blow-Fill-Seal (BFS) Visual Inspection & Leak Detection Machine

A production BFS inspection line follows moulded containers from the forming and sealing process to accepted or rejected product. Cameras assess defined visible defects, while an optional, separately qualified integrity test evaluates its own signal. Strip position, cavity identity and the physical reject destination must remain connected throughout the sequence.

Strip of joined unit-dose plastic ampoules with formed twist-off closures
Connected plastic units travel through inspection as a strip. Define whether a defect means rejecting one cavity or the whole strip.

Blow-Fill-Seal (BFS) Visual Inspection

Inspect the moulded container and preserve its production identity

Plastic seams, wall-thickness variation and reflections form part of the normal BFS image. Lighting and container presentation must reveal the chosen defect against that background. A multi-cavity strip also creates a tracking problem: the system must associate each image and test result with the correct cavity, then reject the correct strip or separated unit according to the agreed handling strategy.

Connected plastic ampoules travelling between guides on a conveyor
Guides support a BFS strip in transit. The cavity pitch and transfer direction must remain consistent between detection and rejection.

Track each inspected BFS container

Optical assessment, integrity testing and physical rejection have separate verification requirements.

Moulded plastic

Views tailored to seams, walls and the opening feature

Cavity identity

Retain the strip or individual-unit relationship

Separate tests

Distinguish visible defects from integrity-test signals

Process challenges

Moulded plastic: translucency, seams and changing wall thickness affect image contrast. A defect library must include acceptable moulding variation as well as actionable defects.

Read details

Moulded plastic: translucency, seams and changing wall thickness affect image contrast. A defect library must include acceptable moulding variation as well as actionable defects.

Particle visibility: product colour, wall texture, bubbles and illumination affect the observed signal. Detection performance must be established with representative defect samples.

Seal assessment: a camera may reveal missing material or visible deformation, but it does not establish closure integrity. The chosen leak-test method requires its own suitability and defect challenges.

Strip rejection: one failed cavity may require rejection of the entire strip. Individual recovery is a separate handling and quality decision, not an assumed machine capability.

Format changes alter cavity spacing, supporting surfaces, camera views and reject timing. A saved recipe does not remove the need to verify physical setup.

Inspection strategy: visual examination and integrity testing answer different questions. Their coverage, acceptance criteria and records belong in the product-specific control strategy.

Production issue Inspection and handling response
Label replenishment Assess the selected labeler and its replenishment sequence; do not infer continuous production or an OEE gain from a dual-reel concept.
Static charge Evaluate product adhesion and handling effects. Any ionization device must be verified in its actual location.
Bubbles and fill level Challenge the intended observation timing with representative bubbles and product levels; avoid treating every moving feature as a particle.
Multi-cavity identity Map each cavity to a view and result, then retain the strip relationship through rejection.
Non-visible leakage Select an integrity method appropriate to the liquid, plastic and seal geometry; visual inspection is not a substitute.
Particle discrimination Use representative particles and acceptable moulding variation to assess detection and false rejection at the proposed working rate.
Format transition Verify supports, camera regions, recipes and reject timing after each physical change.
Print and label assessment Where included, define the content and appearance checks and connect each failed result to a verified reject path.

Technical data & features

Define whether strips or single units are inspected and distinguish mould marks from actionable defects.

Connected plastic ampoules travelling between guides on a conveyor
Technical data & features · Parameter comparison
Configuration element BFS strips Individual BFS containers
Working rate Evaluate complete-strip presentation, cavity imaging and reject timing together. Evaluate spacing, views and rejection for the actual container geometry.
Format inputs Cavity count, pitch, connecting web, wall and seal geometry. Body shape, opening feature, wall and seal geometry.
Optical arrangement Select views and illumination for each cavity without losing strip identity. Select end and side views that suit the container support.
Particle assessment Challenge relevant cavities and positions with representative products and defect samples. Challenge the observed liquid regions and relevant defect positions.
Integrity test Define the method and tested regions independently of vision. Define the method and package presentation independently of vision.
View coverage Record the observed regions and any occlusion caused by connecting webs or holders. Record the observed regions and any occlusion caused by holders or opening features.
Defect classification Separate product particles, wall inclusions, moulding defects and seal appearance. Separate product, body, closure and fill-level observations.
Format change Verify cavity pitch, support, recipes and the strip-to-result association. Verify guide settings, support, recipes and container tracking.
Reject unit Specify whole-strip rejection or separately engineered unit handling. Track each container to the accepted or rejected destination.
Vision utilities Determine electrical and other services from the selected inspection configuration. Determine electrical and other services from the selected inspection configuration.
Integrity-test utilities Determine the requirements of the selected test method and protection system. Determine the requirements of the selected test method and protection system.
Qualification basis Agree product samples, defect challenges, records and operating procedures. Agree product samples, defect challenges, records and operating procedures.
Vision footprint Allow access for strip entry, optics, reject collection and maintenance. Allow access for container entry, optics, reject collection and maintenance.
Integrity-test footprint Allow the required test presentation, safety access and transfer distance. Allow the required test presentation, safety access and transfer distance.
Labeling interface Match label placement and subsequent checks to the strip or unit route. Match label placement and subsequent checks to the selected bottle or ampoule.

How it works

How are moulding marks separated from defects?

Build the trial set from acceptable production variation and representative defects. Adjust lighting and views to reveal the relevant difference, then examine missed defects and false rejects across cavity positions and production conditions.

How is one failed cavity traced to rejection?

Assign the cavity result to its parent strip or tracked separated unit. Challenge the physical reject route with known defects, feed gaps and restarts, and reconcile the collected product with recorded decisions.

How can HVLD be evaluated for a BFS product?

Examine liquid conductivity, the insulating plastic wall, seal geometry and the path through each region to be tested. Use representative defect references and assess product compatibility. Neither an inversion motion nor a nominal voltage proves complete coverage.

How should bubbles be treated during inspection trials?

Use the actual fill, temperature and settling history. Compare bubbles with representative particles under the proposed timing and motion; excluding a region simply because bubbles collect there can also exclude a real defect.

How is a new strip format released for use?

Verify cavity pitch, supports, camera regions, test presentation and reject timing with the new format. Retain the approved setup and challenge results rather than treating recipe selection as sufficient evidence.

How is inspection connected to the BFS machine?

Define the discharge state, cooling or separation steps, buffering and stop/start signals. The interface must preserve product identity and handle blocked discharge, missing strips and reject faults; compatibility is established for the actual upstream machine.

Blow–fill–seal line. Follow the U-shaped route from the forming and filling enclosure to the pallet position. The line provides process context; the individual product is not identified as a separate station in this view.

Production line · Equipment context

Blow–fill–seal line

Explore the process areas on the production line associated with this equipment.

Skip tour
Production layout 6 equipment areas · Scroll to explore

Follow the U-shaped route from the forming and filling enclosure to the pallet position. The line provides process context; the individual product is not identified as a separate station in this view.

Related production lines: Blow-Fill-Seal Pharmaceutical Production Lines · Pharmaceutical Eye Drop Filling Lines · Liquid Inhalation Production Lines

Line integration

From BFS discharge to accepted packaging feed

Upstream: receive cooled, sealed BFS product in the agreed strip or single-unit state. Cooling, trimming and separation occur at the selected point in the production route.

Read more

Upstream: receive cooled, sealed BFS product in the agreed strip or single-unit state. Cooling, trimming and separation occur at the selected point in the production route.

Visual channel: controlled presentation → selected illumination and views → defect decision associated with the cavity or container identity.

Integrity channel, when selected: present the package to a suitable test method and preserve the separate result. HVLD suitability depends on conductive liquid, an insulating package wall and the actual electrical path.

Identification, when selected: label or code accepted product at the agreed stage; verify readable information and track any additional rejection separately.

Downstream: deliver accepted strips or units to the chosen cartoning or bundling route. Segregate rejected product and reconcile physical quantities with inspection records.

Data interface: agree required results, cavity identifiers, event timestamps and communications failure handling. An MES connection is a defined project interface, not an automatic feature.

Support throughout your project and production

Define the equipment scope

Define whether strips or single units are inspected and distinguish mould marks from actionable defects.

Learn more

Agree the acceptance test

Test the lighting and reject path with the full set of cavity positions and representative pack samples.

Learn more

Prepare for operation

Identify the contact parts and format tooling for Blow-Fill-Seal (BFS) Visual Inspection. Agree access for cleaning, the spares to hold and the operating records the site will need.

Learn more

Knowledge hub

2 resources

Frequently asked questions

Is this the same as a QC sample inspection instrument?

No. This page addresses the production transfer, continuous product tracking and physical rejection route. A QC sample instrument has a separately defined sampling and laboratory workflow; similar defect terminology does not make the equipment interchangeable.

Does visual inspection demonstrate a leak-tight BFS seal?

No. A visual result concerns the regions and defects visible to the configured optics. Integrity testing measures a different response and needs an appropriate method, challenge set and acceptance criteria.

Can any BFS liquid be tested by HVLD?

No universal suitability is assumed. The method needs an appropriate electrical response through the liquid and package, with the relevant region in the tested path. Low-conductivity products and unusual geometries require specific assessment.

Must one failed cavity cause rejection of the whole strip?

That depends on the supplied handling arrangement and quality strategy. Whole-strip rejection is one option; recovering individual cavities requires an engineered separation and traceability procedure.

Can a detection limit be stated before sample trials?

A single particle or leak dimension does not describe performance across all products and positions. Establish detection and false-reject behaviour using defined defects, actual packages and the intended operating conditions.

Contact

For a configuration review, include container drawing, product-contact materials, intended dose, closure format, batch size.

Discuss your project
Connected plastic ampoules travelling between guides on a conveyor